| Height |
23 inches |
| Depth |
23 inches |
| Width |
17 inches |
| Weight |
|
Free-Standing |
45 LBS |
| Materials |
Aluminum, brass and plastic |
| Operating Temperature Range |
35 to 110 degrees, F. |
| Gas Supply Sources |
|
| O2 Main and Cylinders |
38-70 psi (50 psi is optimal) |
| Air and/or Air Compressor |
38-70 psi (50 psi is optimal) |
| Oxygen Concentrator |
3-10 psi |
| Fresh Gas Flow |
1 to above 20 lpm (each flowmeter) |
| Oxygen Flush Valve |
Recessed, self-closing, push button
color coded and labeled, provides 45-55 L/min. flow while depressed |
| CO2 Absorber System |
King Systems KAB-9 (re-fillable), or KAB-1 (prefilled/disposable) |
| C02 Absorber Capacity |
400 grams soda-lime |
| Directional Valves |
Built-in the CO2 absorber |
| CO2 Absorber Holding Bracket |
Plastic, secured with knob to main frame of machine |
| Bag-Ventilator Switch/PVR and Scavenger Outlet
Port |
Hand-operated selector switch and rotating knob
for PRV and Scavenging outlet |
| Bellows |
Latex free, upward inflating, range from
0 to 1.6L |
| Bellows Presure Relief |
Pre-set at 60 cmH20 |
| Common Gas Outlet |
Size indexed, quick connect |
| Tubing Circuit |
King Systems F-360-61 or any standard anesthesia
circle system |
| Gas Pressure Hoses |
DISS/thread indexed, female connectors at both
ends |
| Gas Inlet Manifold |
DISS/thread indexed, male connectors with one
way valves |
| Gas Inlet Manifold Filters |
Located behind Manifold Air and O2 inlet male
connectors |
| Oxygen and Air Supply Gauges |
0-3000 PSI reading color coded and clearly labeled |
| Gas Inlet Pressure Regulators |
0-3000 PSI reading color coded and clearly labeled |
| Main Supply Cylinder |
DIS S/threaded indexed for O2 |
| Safety back up Cylinder |
Pin Indexed, yoke mounted for "D" and
"E" cylinders for O2 |
| Oxygen Supply Failure Alarm |
|
| Main and Safety Supply |
Pneumatically actuated when O2 supply falls below
35 psi |
| O2 Concentrator |
Pneumatically actuated when O2 supply falls below
1 psi |
| Alarm Power Source |
9 volt battery located in body of alarm box |
| Alarm On/Off |
Labeled toggle switch located on body of alarm
box |
| Oxygen and Air Flowmeters
|
Calibrated and scaled 0-10 LPM color coded. O2
flowmeter has a fluted control Knob for easy identification
by touch |
| Oxygen Concentrator |
To power O2 flowmeter only |
| Auxiliary Oxygen Flowmeter |
Scaled 0-15LPM color coded and clearly
labeled |
| Air Compressor |
May be used to power ventilator and air flowmeter |
| Auxillary O2 Flow Selector |
Scaled 0-10 LPM in set increments, used for pre/post
anesthesia |
| Vaporizer |
Penlon Delta-Sigma Series, bolt (cage)
mounted, temperature compensated,
very low maintenance |
| Airway Pressure Gauge |
Dual Scaled in cmH2O and mmHg, located
on front panel of ventilator |
| Pressure Guage Tubing |
Attached to bag/vent switch arm |
| Mechanical Ventilator |
Pneumaticaly powered, time cycled,
volume constant, pressure variable |
| Ventilator Pressure Relief |
Dual scaled in cmH2O and mmHg, Located
onn front panel of ventilator |
| Volume Range |
0 to 1.6 L |
| Insp. Flow Range |
0 to .90 lps |
| Insp. Time Range |
.2 to 3.0 seconds |
| Exp Time Range |
.2 to 3.0 seconds |
| Ventilator Gas Power |
40 to 70 psi (50 psi optimal) |
| Requirements |
Use toggle switch to select gas source |
| Wate Gas Scavanger |
Positive and negative relief valves,
1 L resivoir bag, vacuum control knob |
| Total System
Leakage |
@ 30cm H2O 0ML/min
@ 80cm H2O 0ML/min |
| Internal
System Compliance |
@ 20cm H2O 1.1ML/cm
H2O
@ 40cm H2O 1.3ML/cm H2O |
| Internal System
Resistance |
@ 1.0L/sec gas
flow 4.11cm H2O
@ 0.5L/sec gas flow 1.80cm H2O |
| APL Valve Pressure
Drop |
@ 3.0L/min gas
flow 0.12cm H2O
@ 30L/min gas flow 1.03cm H2O |
| Adjustable Pressure-Limit
|
Adjustable, 0 to
40 cmH2O |
| Storage |
|
| Indoor |
+160 degrees Allow unit to warm to
normal |
| Outdoor |
-30 degrees O.R. temp for 1 hour |
This anesthesia
machine is designed to be used in conjunction with a monitoring
system of your choosing. |